知识导航
资源分类

浅谈对大型抽水蓄能机组顶盖螺栓预紧力的认识

浅谈对大型抽水蓄能机组顶盖螺栓预紧力的认识

Analysis of the Headcover Bolt's Pretightening Force of the Large Pumped Storage Unit

Analysis of the Headcover Bolt's Pretightening Force of the Large Pumped Storage Unit

doi:
10.3969/j.issn.2096-093X.2018.01.003
摘要:
近几年,国内外均发生少数电站水轮机顶盖把合螺栓断裂造成水淹厂房的事故,引起了有关方面的高度重视,也对球阀、顶盖等水轮机关键部位的紧固螺栓设计强度提出了更高的要求.本文探析了螺栓连接的预紧力、残余预紧力以及工作载荷之间的逻辑关系并尝试总结提出一些认知性的粗浅看法,仅提供与有关同仁商榷.
Abstract:
In recent years,some powerhouse floodingevents caused by bolt fracture of the headcover has occurred in some hydroelectric power stations at home and abroad.afterwards,the relevant fields have attached great importance to it.And the design strength of the fastening bolts for the key parts of the water turbine,such as the ball valve and the top cover,has been also put forward higher standards.This paper analyzes and compares the design standards of various related specifications and some manufacturers,studies on the relationship between pretightening force,remainder pretightening force and working load of bolted connection,and tries to sum up some superficial views.It only provides reference for relevant design staff.
作者 何少润 [1] 陈泓宇 [2] 杨昭 [2] 顾志坚 [2] 陈志明 [2] 张良 [2]
Author: HE Shaorun[1] CHEN Hongyu[2] YANG Zhao[2] GU Zhijian[2] CHEN Zhiming[2] ZHANG Liang[2]
作者单位
  1. 中国南方电网调峰调频发电公司,广东省广州市,510640
  2. 深圳蓄能发电有限公司,广东省深圳市,518115
期 刊: 水电与抽水蓄能 ISTIC EI SCI PKU CSSCI
Journal: Hydropower and Pumped Storage
年,卷(期) 2018, 4(1)
分类号 TV734
关键词: 抽水蓄能机组 知识脉络 螺栓连接 知识脉络 预紧力 知识脉络 屈服应力 知识脉络 残余预紧力 知识脉络 工作载荷 知识脉络
Keywords: pumped storageunits bolted connection pretightening force yield stress remainder pretightening working load